View cart “Chauvin Arnoux : C.A 832 Sound Level Meter” has been added to your cart.

TSI Airflow Instruments : TA440-A Velocity Meter

Availability: in stock 0 items(s)
Product Code: AF-AF-023

The TA440-A includes an articulated probe– all in one compact package. Ideal applications include HVAC system performance, commissioning, plant maintenance, critical environment certification and duct traverses.

Download PDF

RM9,980.00

Available on backorder

CompareCompare

Additional Features and Benefits
+ Simultaneously measures temperature and velocity
+ Displays up to three measurements simultaneously
+ Calculates volumetric flow, and actual/standard velocity
+ Articulated probe versions available
+ Data logging and LogDat2™ downloading software included
+ Measures humidity (TA440), wet bulb, and dewpoint temperature

Applications
+ HVAC system performance
+ Commissioning
+ Plant maintenance
+ Critical environment certification
+ Duct traverses

There are no reviews yet.

Be the first to review “TSI Airflow Instruments : TA440-A Velocity Meter”

Questions and answers of the customers

There are no questions yet, be the first to ask something for this product.

Velocity
Range (TA410): 0 to 20 m/s (0 to 4,000 ft/min)
Range (TA430, TA440): 0 to 30 m/s (0 to 6,000 ft/min)
Accuracy (TA410)¹&²: ±5% of reading or ±0.025 m/s (±5 ft/min), whichever is greater
Accuracy (TA430, TA440)¹&²: ±3% of reading or ±0.015 m/s (±3 ft/min), whichever is greater
Resolution: 0.01 m/s (1 ft/min)
Duct Size (TA430, TA440)
Dimensions: 1 to 635 cm in increments of 0.1 cm (1 to 250 inches in increments of 0.1 in.)
Volumetric Flow Rate (TA430, TA440)
Range: Actual range is a function of velocity, and duct size
Temperature
Range (TA410, TA430): -18 to 93°C (0 to 200°F)
Range (TA440): -10 to 60°C (14 to 140°F)
Accuracy³: ±0.3°C (±0.5°F)
Resolution: 0.1°C (0.1°F)
Relative Humidity (TA440 only)
Range: 5 to 95% RH
Accuracy⁴: ±3% RH
Resolution: 0.1% RH
Wet Bulb Temperature (TA440 only)
Range: 5 to 60°C (40 to 140°F)
Resolution: 0.1°C (0.1°F)
Dew Point (TA440 only)
Range: -15 to 49°C (5 to 120°F)
Resolution: 0.1°C (0.1°F)
Instrument Temperature Range
Operating (Electronics):  5 to 45°C (40 to 113°F)
Model TA410, TA430: -18 to 93°C (0 to 200°F)
Operating (Probe)
Model TA440: -10 to 60°C (14 to 140°F)
Operating (Probe)
Storage: -20 to 60°C (-4 to 140°F)
Data Storage Capabilities (TA430, TA440)
Range: 12,700+ samples and 100 test IDs
Logging Interval (TA430, TA440)
1 second to 1 hour
External Meter Dimensions
8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.)
Meter Weight with Batteries
0.27 kg (0.6 lbs.)
Meter Probe Dimensions
Probe Length: 101.6 cm (40 in.)
Probe Diameter: of Tip 7.0 mm (0.28 in.)
Probe Diameter: of Base 13.0 mm (0.51 in.)
Articulating Probe Dimensions
Articulating Section 19.7 cm (7.8 in.)
Length
Diameter of 9.5 mm (0.38 in.)
Articulating Knuckle
Power Requirements
Four AA-size batteries or AC adapter